An epoxy floor that looks tired is often still doing its job. If it is firmly bonded, it can be refreshed with a clear top coat instead of being ground off and replaced. The condition of the old epoxy decides whether that will work.

Three checks before anything else

  1. Bond. Walk the floor and tap it. Look at joints, edges and wheel paths. Peeling, hollow-sounding areas and blisters mean the epoxy has let go.
  2. Contamination. Oil, grease and tyre marks stop a new coat bonding. Surface dirt can be degreased. Epoxy that is soaked through cannot.
  3. Wear. Scuffs and dull patches are fine. Areas worn through to bare concrete need the epoxy system rebuilt there first.

If the epoxy fails the first check, the cause must be found before recoating. The guide to epoxy floor peeling and delamination covers that.

How the upgrade is done

  1. Repair. Cut out loose areas and rebuild them with the original system. Fill cracks and damaged joints.
  2. Clean and degrease the whole floor.
  3. Abrade to a uniform matt key. No glossy patches should remain.
  4. Vacuum thoroughly.
  5. Test area. Apply the clear coat to a small area and confirm it has bonded before coating the rest.
  6. Apply one coat of TopShield CH465-S at 0.10 kg/m².

TopShield CH465-S is a two-part clear ceramic-hybrid top coat, mixed 3:1 by weight, at about 50 µm per coat. It takes foot traffic after 12 hours and reaches full hardness after 72 hours at 20 °C. Its data sheet lists existing epoxy floors as a substrate, with a test area first.

What the clear coat adds, and what it does not

It addsIt does not
A harder, stain-resistant wearing surfaceHide scratches, stains or colour differences
A surface that is easier to cleanLevel a rough floor or bridge moving cracks
A renewed wearing surface over the old colourFix peeling or blistering below it

When to choose something else

  • The floor must look new. Apply a fresh colour coat first, then the clear coat.
  • The floor is in direct sun. Epoxy chalks and yellows in sunlight, and Rayson has not published UV data for the ceramic-hybrid coat. Use an aliphatic polyurethane clear coat such as TopShield PU425-S.
  • The floor is wet in use. A smooth clear coat can be slippery when wet. Ask about an anti-slip finish.
  • Hot wash-down or thermal shock. That calls for a PU-cement screed, not a thin film.

Getting it assessed

Send photos of the whole floor and close-ups of the worst areas, with the area and what runs on it. Rayson recommends the job to an applicator in its network, who quotes and contracts it with you directly. TopShield CH465-S is new in the Rayson range in November 2026, so ask about availability and a test area. The other systems for bare concrete are on the concrete floor sealer page.