Rayson SealForce Polyurethane-modified Interior & exterior

Rayson SealForce PU510-W

Rayson SealForce PU510-W is a one-part, water-based, polyurethane-modified waterproofing membrane for toilets, showers, bathrooms, balconies and other interior wet areas — rolled or brushed on in two coats and concealed beneath the tiles, screed or render.

Best for

Best for concealed waterproofing before tiling in toilets, bathrooms and wet areas, and beneath the screed on balconies and terraces, where a ready-to-use, low-odour membrane is wanted in an occupied home or building.

Product packaging · Interactive depth view Rayson SealForce
Rayson SealForce PU510-W pail and label
Move to inspect the product
Product system Rayson SealForce PU510-W
20 kg plastic pail RY-TDS-PU510
Why specify Rayson SealForce PU510-W

Rayson SealForce PU510-W has one clearly defined, verifiable job in the coating system.

Rayson SealForce PU510-W is a one-part, water-based, polyurethane-modified waterproofing membrane for toilets, showers, bathrooms, balconies and other interior wet areas — rolled or brushed on in two coats and concealed beneath the tiles, screed or render. Best for concealed waterproofing before tiling in toilets, bathrooms and wet areas, and beneath the screed on balconies and terraces, where a ready-to-use, low-odour membrane is wanted in an occupied home or building.

01

One-part and ready to use — no mixing, no dilution, no solvent odour

Concealed waterproofing of toilets, showers and bathrooms before tiling

02

Elongation ≥150% and crack-bridging over 2 mm cracks

Terraces and balconies beneath screed and tile finishes

03

Nil water penetration under pressure at the specified film build

Kitchens, laundries, yards and all other interior wet areas

SealForce PU510-W trial batch applied across a hacked HDB toilet floor and up the walls, around the soil stack and floor outlet, before the flood test and tiling
SealForce PU510-W trial batch · HDB toilet, September 2026

Apply. Turn up. Flood-test. Then tile.

A pre-launch trial batch of SealForce PU510-W on a hacked HDB toilet floor in Hougang — turned up the walls and detailed around the stack, outlet and pipe cores, then flood-tested the following day. Photographed by Rayson, September 2026.

Hacked HDB toilet floor in Hougang coated with SealForce PU510-W green waterproofing membrane, turned up the walls around the soil stack and WC outlet
Seen on site

Applied and flood-tested in an HDB toilet in Hougang, September 2026.

A pre-launch trial batch of SealForce PU510-W was rolled across a hacked HDB toilet floor the day after demolition, turned up the walls and dressed around the soil stack, the WC outlet and the pipe cores, then flood-tested 24 hours after the final coat before the tile bed went down. Five site photographs show the membrane and the test. It is a controlled trial record, not a completed-project claim.

From substrate to service

A controlled route to applying Rayson SealForce PU510-W.

This sequence supports early planning. It does not replace the current Technical Data Sheet, approved method statement or project-specific technical review.

  1. 01

    Inspect and prepare the substrate

    Concrete floors and walls at least 28 days old

  2. 02

    Prepare the material as specified

    One part — stir gently before use and apply straight from the pail; do not dilute and do not add sand

  3. 03

    Apply with the correct tools

    Recommended methods: Roller, Brush. Confirm coat count and thickness for the project.

  4. 04

    Protect through the required cure

    Touch dry in under 60 minutes; first coat dry in 1–2 hours, second coat in about 4 hours depending on temperature and humidity; ponding test 24 hours after the final coat

Coating system cutaway

Every layer has a job—from prepared substrate to service surface.

This diagram explains a typical system position, not a fixed specification. Primer, body coat, finish, thickness and detailing must be confirmed for the project.

Position in the system Standalone coating

Rayson SealForce PU510-W serves as the standalone coating. Confirm the complete build-up against the substrate, exposure and project requirements.

Related system products

Review primers, body layers, finishes or specialist components connected to this product.

  1. Rayson SealForce PU510-WStandalone coating · Polyurethane-modified
  2. Approved primer / baseIncluded when required by the system design
  3. Correctly prepared substrateConcrete floors and walls at least 28 days old
Technical planning data

Four project facts for faster system screening.

These current product figures support early selection. Confirm the final build-up, quantity and application conditions against the Technical Data Sheet and site conditions.

Coverage
Coverage

Approximately 0.56 kg/m² per coat at 0.4 mm wet film (about 1.8 m² per kg); a 20 kg pail covers about 36 m² per coat, or about 18 m² at two coats, subject to substrate condition

Mixing & working time
Mixing

One part — stir gently before use and apply straight from the pail; do not dilute and do not add sand

Drying & curing
Curing

Touch dry in under 60 minutes; first coat dry in 1–2 hours, second coat in about 4 hours depending on temperature and humidity; ponding test 24 hours after the final coat

Pack configuration
Pack

20 kg plastic pail

Suitability check

Confirm the substrate and real service environment before specifying.

01

Choose it when

  • Concealed waterproofing of toilets, showers and bathrooms before tiling
  • Terraces and balconies beneath screed and tile finishes
  • Kitchens, laundries, yards and all other interior wet areas
  • Re-waterproofing of wet areas during renovation once the finishes are removed

Relevant applications

Relevant industries

02

Choose something else when

  • Concealed membrane — protect with screed, render or tiling after the ponding test; not for exposed or trafficked service
  • Apply only between 10 °C and 45 °C on a dry substrate
  • Not suitable where negative hydrostatic pressure is evident
  • Do not dilute and do not add sand — both reduce flexibility and can cause cracking
  • Provide falls to prevent ponding; carry out the ponding test 24 hours after the final coat
  • Minimum two coats at 0.4 mm wet film each; a third coat may be needed for a pinhole-free film
  • Exposed roofs, decks or any surface left uncovered — the membrane must be protected
  • Trafficked floors without a wearing system above the membrane
  • Substrates with negative hydrostatic pressure or standing water
  • Application below 10 °C or above 45 °C, or onto damp, dusty or unsound substrates

Other Rayson products to evaluate

These links continue the comparison; they are not automatic substitutes. Confirm the substrate, exposure and complete build-up before selection.

Substrate requirements
  • Concrete floors and walls at least 28 days old
  • Cement-sand render and screed cured at least 7 days
  • Existing concrete, degreased, pressure-washed and fully dried
  • Substrates must be structurally sound, dry and free of curing compounds, loose material and protrusions
Technical documents and project support

Ready to specify Rayson SealForce PU510-W? Give Rayson the site conditions.

Send the area, substrate condition, expected traffic or exposure, required finish and programme. The technical team can help review the system build-up and estimated quantity.

Common technical questions

What to know before specifying Rayson SealForce PU510-W.

Do I need a primer under SealForce PU510-W?

No. It is a one-part membrane applied directly to a sound, clean, dry concrete or rendered substrate — there is no separate primer in the system. Preparation does the primer's job: remove loose material, curing compounds and protrusions, and let old concrete dry fully after washing. SealForce AC505-W, the acrylic primer in the range, belongs to the SealForce AC540-W roof and wall system, not to PU510-W.

How many coats, and how thick?

At least two coats at 0.4 mm wet film each, rolled or brushed straight from the pail, the second 1–2 hours after the first. Add a third coat where the film is uneven or pinholes remain. A 20 kg pail covers about 36 m² per coat.

Can tiles be laid directly on it?

Only after the ponding test, 24 hours after the final coat, has proved the membrane — and always through the screed, render or tile bed that protects it. The membrane is not a wearing surface and must never be left exposed. Rayson SealForce LX560-W can be mixed into that screed, render and tile bed to make them stronger and more water-resistant.

What is the difference between SealForce PU510-W and SealForce PA525-S?

PU510-W is a one-part, water-based membrane for concealed wet areas — toilets, bathrooms and balconies beneath tiles — chosen for ease of use and low odour in occupied homes. PA525-S is a two-component polyurea-based membrane with higher elongation and heat resistance for decks, roofs and heavier-duty wet areas.

Can it be used where water pressure comes from behind the surface?

No. SealForce PU510-W is a positive-side membrane and must not be used where negative hydrostatic pressure is evident, such as a basement wall with groundwater behind it. Those conditions need a tanking or crystalline system designed for them.

How long does the job take, and when can the floor be walked on or tiled?

Each coat is touch dry in under 60 minutes at laboratory conditions; the second coat goes on 1–2 hours after the first and is dry in about 4 hours. The flood (ponding) test is carried out 24 hours after the final coat, with light foot traffic only, and the screed or tile bed follows once the test has held. In a typical HDB toilet the membrane is one day of work and the test the next.

Can SealForce PU510-W be applied without hacking the tiles?

No. It is a concealed membrane applied to the prepared screed or concrete beneath the tiles, not a coating over them. If the bathroom has failed an HDB or HIP water test, water is already under the tiles and no surface-applied product reaches the failed detail: the tiles come up, the substrate is prepared, and PU510-W is applied in two coats and flood-tested before re-tiling. The wet-area guide sets out when a no-hack repair is honest and when it is not.

What should the waterproofing line of a toilet quotation say?

The product by name — Rayson SealForce PU510-W — two coats at 0.4 mm wet film each (about 0.56 kg/m² per coat), the turn-up height on every wall and at the door threshold, the detailing at the floor trap, pipe penetrations and wall–floor junction, a 24-hour flood test before tiling, and who carries which warranty: the applicator for workmanship, Rayson for the material, three years against manufacturing defects when applied per the TDS. A quotation that says only "waterproofing" cannot be compared with another.

How much SealForce PU510-W does an HDB toilet need?

About 8 to 12 kg for two coats over a typical 3 m² toilet floor with 300 mm turn-ups and a shower wall taken to 1.8 m — under one 20 kg pail, which covers about 18 m² at two coats. Detailing, a third coat on thin patches and wastage set the actual figure; the coverage calculator gives the theoretical quantity for any area.

How long does SealForce PU510-W last?

Rayson does not publish a service-life figure for a concealed membrane: the tile bed protects the film, and it is the details that fail, not the field. What the data shows is retention — at least 1.0 N/mm² tensile strength and 120% elongation after ageing at 50 °C and after 72 hours in hypochlorite, ammonia or dilute acid. A bathroom lasts as long as its trap, penetrations and turn-ups were done correctly and flood-tested before the tiles went down.

Is SealForce PU510-W available to order now?

SealForce PU510-W is part of Rayson's upcoming waterproofing release, and a pre-launch trial batch has already been applied and flood-tested in a Singapore HDB toilet. Send the project details and your required date, and Rayson will confirm supply timing, quantities and, where you need the work done, the applicator in its network who will quote the installation, before you commit.

Related products

Rayson SealForce PA525-S — Waterproofing primer, membranes & additive
Waterproof SealForce

Rayson SealForce PA525-S

Two-part · 25 kg + 1.5 kg

Rayson SealForce PA525-S is a two-component, roller-applied polyurea-based liquid waterproofing membrane — highly elastic and hydrophobic, bonding strongly to concrete, tile, metal and asphalt for wet areas, roofs and car parks.

Surfaces
Concrete, Cement screed
Chemistry
Polyurea
Rayson SealForce LX560-W — Waterproofing primer, membranes & additive
Waterproof SealForce

Rayson SealForce LX560-W

Latex additive · 20 kg

Rayson SealForce LX560-W is a one-part latex waterproofing and bonding additive for cement-based work — mixed into renders, screeds, slurry coats, tile adhesives and grout to cut water penetration, strengthen the mortar and improve its bond and flexibility.

Surfaces
Concrete, Cement screed
Chemistry
Latex
Rayson SealForce PA520-S — Waterproofing primer, membranes & additive
Waterproof SealForce

Rayson SealForce PA520-S

Two-component kit · 5.25 or 21 kg

Rayson SealForce PA520-S is a two-component, cold-applied aliphatic polyurea waterproofing membrane for exposed roofs — roller-, brush- or spray-applied, UV-stable and walkable, with certified cool-roof reflectance.

Surfaces
Roofs, Concrete
Chemistry
Polyurea
Rayson PatchBond EP220 — Repair mortars & compounds
Repair PatchBond

Rayson PatchBond EP220

Two-part epoxy repair system

Rayson PatchBond EP220 is a two-component, solvent-free thixotropic epoxy adhesive and repair compound with exceptional sag resistance that bonds and fills on vertical, overhead and even mat-damp concrete surfaces.

Surfaces
Concrete, Walls
Chemistry
Epoxy