Rayson SealForce Acrylic Exterior

Rayson SealForce AC505-W

Rayson SealForce AC505-W is a one-part, water-based acrylic primer for the SealForce waterproofing range — brushed or rolled onto concrete, render, brick, stone and roof tiles to seal pores, bind dust and give SealForce AC540-W a firm surface to bond to.

Best for

Best for absorbent, dusty or smooth surfaces on roofs and external walls — concrete, render, brick, stone and unglazed or clay tiles — before the SealForce AC540-W acrylic membrane goes on.

Product packaging · Interactive depth view Rayson SealForce
Rayson SealForce AC505-W pail and label
Move to inspect the product
Product system Rayson SealForce AC505-W
20 kg pail RY-TDS-AC505
Why specify Rayson SealForce AC505-W

Rayson SealForce AC505-W has one clearly defined, verifiable job in the coating system.

Rayson SealForce AC505-W is a one-part, water-based acrylic primer for the SealForce waterproofing range — brushed or rolled onto concrete, render, brick, stone and roof tiles to seal pores, bind dust and give SealForce AC540-W a firm surface to bond to. Best for absorbent, dusty or smooth surfaces on roofs and external walls — concrete, render, brick, stone and unglazed or clay tiles — before the SealForce AC540-W acrylic membrane goes on.

01

One-part and water-based — stirred and applied straight from the pail by brush or roller

Primer for absorbent concrete, render, brick, stone and tiles before SealForce AC540-W

02

Improves the bond of SealForce AC540-W to concrete, render, masonry and tiles

Bonding primer on smooth, dense concrete finishes

03

Seals pores so the membrane cures without bubbles or pinholes

Binding surface dust and firming weak surface layers before the membrane

Seen on site · Application trial

Before the membrane, the primer.

Four stills from a Rayson application trial on a metal roof in Singapore, October 2026. On an existing coating, the AC540-W data sheet asks for a trial area before the full job; this record is that step, not a finished project.

Products
SealForce AC505-W primer, then SealForce AC540-W membrane
Surface
Profiled metal roof sheet with an old red coating, beside a wall
Record
Application trial in Singapore, October 2026, photographed on site
  1. Before the SealForce AC505-W and AC540-W application trial on a metal roof in Singapore, October 2026: a worn, flaking red coating on the profiled roof sheet beside a wall, with the wall junction open. The roof as found, before cleaning, primer or membrane.

    Step 1: Existing condition

    Worn red coating on a profiled metal roof sheet, and an open junction where it meets the wall. Photographed before work began.

  2. The same red-coated metal roof sheet after sweeping and mopping during the trial, still wet. Cleaning removes dust and loose material; it does not establish that the old coating is sound.

    Step 2: Cleaned

    Swept and mopped during the trial; the roof is still wet here. Cleaning is one part of preparation, not all of it.

  3. SealForce AC505-W acrylic waterproofing primer roller-applied over the existing red coating of a metal roof along the wall, seen as a thin milky-white film. AC505-W dries clear and is always covered by the SealForce AC540-W membrane. Application trial, Singapore, October 2026.

    Step 3: AC505-W · Primer This product

    SealForce AC505-W rolled over the old coating. It goes on milky white and dries clear: the primer, not the waterproofing layer.

  4. SealForce AC540-W one-part acrylic roof waterproofing membrane roller-applied in white over the primed metal roof sheet, worked into the wall junction first and then across the profile. Application trial, Singapore, October 2026; an application stage, not the finished coat count.

    Step 4: AC540-W · Membrane SealForce AC540-W

    SealForce AC540-W rolled into the wall junction and out across the roof profile: the detail first, then the open area.

What the photos show

  • The metal roof as found, including the wall junction
  • AC505-W applied as a primer film before the membrane
  • AC540-W worked into the junction and across the roof profile

What they cannot tell you

  • Whether the old coating is sound, and the metal under it
  • The coat count, film thickness or cure
  • How the system performs over time

Check the system for your surface.

An existing coating needs an adhesion and compatibility check, and bare metal needs the specified anti-corrosion primer: AC505-W is not a metal primer. Follow the current TDS for the full build-up.

Stills from the trial footage, cropped to the work area; nothing added or removed. An application trial, not a completed project or a long-term performance claim.

From substrate to service

A controlled route to applying Rayson SealForce AC505-W.

This sequence supports early planning. It does not replace the current Technical Data Sheet, approved method statement or project-specific technical review.

  1. 01

    Inspect and prepare the substrate

    Concrete and cementitious surfaces: sound, with a pull-off strength of at least 1.5 N/mm², at least 28 days old and mechanically prepared to an open texture

  2. 02

    Prepare the material as specified

    One part, ready to use — stir for at least 1 minute with a slow paddle until uniform, without whipping in air

  3. 03

    Apply with the correct tools

    Recommended methods: Brush, Roller. Confirm coat count and thickness for the project.

  4. 04

    Protect through the required cure

    Dry when the milky white has turned clear — about 30 minutes, longer in cool or humid weather. Apply SealForce AC540-W once it has dried clear. Protect from rain until dry

Coating system cutaway

Every layer has a job—from prepared substrate to service surface.

This diagram explains a typical system position, not a fixed specification. Primer, body coat, finish, thickness and detailing must be confirmed for the project.

Position in the system Primer

Rayson SealForce AC505-W serves as the primer. Confirm the complete build-up against the substrate, exposure and project requirements.

Related system products

Review primers, body layers, finishes or specialist components connected to this product.

  1. Rayson SealForce AC505-WPrimer · Acrylic
  2. Approved primer / baseIncluded when required by the system design
  3. Correctly prepared substrateConcrete and cementitious surfaces: sound, with a pull-off strength of at least 1.5 N/mm², at least 28 days old and mechanically prepared to an open texture
Technical planning data

Four project facts for faster system screening.

These current product figures support early selection. Confirm the final build-up, quantity and application conditions against the Technical Data Sheet and site conditions.

Coverage
Coverage

Approximately 0.1–0.3 kg/m² per coat, depending on absorbency; a 20 kg pail primes about 65–200 m² per coat. Very porous surfaces take a second coat

Mixing & working time
Mixing

One part, ready to use — stir for at least 1 minute with a slow paddle until uniform, without whipping in air

Drying & curing
Curing

Dry when the milky white has turned clear — about 30 minutes, longer in cool or humid weather. Apply SealForce AC540-W once it has dried clear. Protect from rain until dry

Pack configuration
Pack

20 kg pail

Suitability check

Confirm the substrate and real service environment before specifying.

01

Choose it when

  • Primer for absorbent concrete, render, brick, stone and tiles before SealForce AC540-W
  • Bonding primer on smooth, dense concrete finishes
  • Binding surface dust and firming weak surface layers before the membrane
  • Sealing pores in rough concrete so the membrane cures without bubbles or pinholes

Relevant applications

Relevant industries

02

Choose something else when

  • A primer, not a waterproofing layer: always cover it with SealForce AC540-W
  • Apply between +5 °C and +40 °C, at no more than 80% relative humidity, with the substrate at least 3 °C above the dew point
  • Substrate moisture at most 6% by weight; no standing water and no rising moisture
  • Protect from rain until dry
  • Not for use under the polyurea membranes — SealForce PA520-S, PA525-S, PA530 and PA535 take the primer named in their own data sheets
  • Metal needs an anti-corrosion primer instead; on glazed tiles, sound old coatings or other dense surfaces, confirm adhesion with a trial area first
  • Floors under water-based urethane finishes — use Rayson PrimeBond AC130-W
  • Under the polyurea membranes SealForce PA520-S, PA525-S, PA530 and PA535
  • Under SealForce PU510-W in toilets and bathrooms, which needs no primer
  • Use on its own as a sealer or finish — it must be covered by SealForce AC540-W

Other Rayson products to evaluate

These links continue the comparison; they are not automatic substitutes. Confirm the substrate, exposure and complete build-up before selection.

Substrate requirements
  • Concrete and cementitious surfaces: sound, with a pull-off strength of at least 1.5 N/mm², at least 28 days old and mechanically prepared to an open texture
  • Brick and stone with sound, flush-pointed mortar joints; loose units replaced
  • Unglazed ceramic tiles and clay roof tiles, securely fixed, with broken or missing tiles replaced
  • All surfaces power-washed or vacuumed free of dust, and dry: moisture at most 6% by weight, with no standing water or rising moisture
Technical documents and project support

Ready to specify Rayson SealForce AC505-W? Give Rayson the site conditions.

Send the area, substrate condition, expected traffic or exposure, required finish and programme. The technical team can help review the system build-up and estimated quantity.

Common technical questions

What to know before specifying Rayson SealForce AC505-W.

What is SealForce AC505-W used for?

It prepares concrete, render, brick, stone and roof tiles for SealForce AC540-W, the acrylic roof and wall membrane: a bonding primer on smooth concrete, a pore sealer on rough concrete, and a dust binder on weathered masonry and tiles. It is brushed or rolled on, dries clear and is always covered by the membrane.

Which Rayson waterproofing membranes need it?

SealForce AC540-W, on concrete, render, brick, stone and tiles. SealForce PU510-W does not: it goes straight onto the prepared screed or concrete of a toilet or bathroom. The polyurea membranes, SealForce PA520-S, PA525-S, PA530 and PA535, each take the primer named in their own data sheets, not AC505-W. Metal under AC540-W takes an anti-corrosion metal primer.

How much do I need?

About 0.1 to 0.3 kg/m² per coat, depending on how absorbent the surface is; a 20 kg pail primes about 65 to 200 m² per coat. Very porous concrete, brick or tiles take a second coat, and a small test area shows the real figure for each surface.

How long before the membrane goes on?

Until the milky white has turned completely clear: about 30 minutes, longer in cool or humid weather. Then apply SealForce AC540-W, cleaning off any dust that has settled first. Protect the primer from rain until it is dry.

Can it go on old roof tiles, brick or stone?

Yes, once the surface is sound: loose tiles or bricks fixed, broken ones replaced, open joints pointed, and the surface power-washed and dried. It suits unglazed ceramic and clay tiles; on glazed tiles or other dense surfaces, a trial area confirms adhesion first.

SealForce AC505-W or PrimeBond AC130-W: what is the difference?

Both are one-part, water-based acrylic primers, for different systems. AC505-W is the SealForce waterproofing primer for roofs and external walls under SealForce AC540-W. PrimeBond AC130-W is the floor primer under Rayson's low-odour water-based urethane finishes, such as TopShield PU440-W.

Can it be left on its own as a sealer?

No. It binds dust and seals pores ahead of the membrane, but it is not a waterproofing layer or a wearing surface. It must be covered by SealForce AC540-W.

Is SealForce AC505-W available to order now?

SealForce AC505-W is part of Rayson's upcoming waterproofing release, alongside SealForce AC540-W. Send the project details and your required date, and Rayson will confirm supply timing, quantities and, where you need the work done, the applicator in its network who will quote the installation, before you commit.

Related products

Rayson SealForce AC540-W — Waterproofing primer, membranes & additive
Waterproof SealForce

Rayson SealForce AC540-W

One-part acrylic · 20 kg

Rayson SealForce AC540-W is a one-part, water-based acrylic waterproofing membrane for exposed roofs, old roof tiles and external walls — applied cold, straight from the pail, by brush, roller or airless spray, and drying to a seamless, elastic, UV-resistant film.

Surfaces
Roofs, Walls
Chemistry
Acrylic
Rayson PatchBond EP220 — Repair mortars & compounds
Repair PatchBond

Rayson PatchBond EP220

Two-part epoxy repair system

Rayson PatchBond EP220 is a two-component, solvent-free thixotropic epoxy adhesive and repair compound with exceptional sag resistance that bonds and fills on vertical, overhead and even mat-damp concrete surfaces.

Surfaces
Concrete, Walls
Chemistry
Epoxy
Rayson SealForce PU510-W — Waterproofing primer, membranes & additive
Waterproof SealForce

Rayson SealForce PU510-W

One-part · water-based · 20 kg

Rayson SealForce PU510-W is a one-part, water-based, polyurethane-modified waterproofing membrane for toilets, showers, bathrooms, balconies and other interior wet areas — rolled or brushed on in two coats and concealed beneath the tiles, screed or render.

Surfaces
Concrete, Cement screed
Chemistry
Polyurethane-modified