Draft data sheet. Hardness, abrasion and chemical resistance are described without test figures; the test reports and the Safety Data Sheet (hazard classification, flash point, VOC) are in preparation — confirm with the Rayson technical team.
Rayson TopShield CH465-S is a two-part, clear inorganic–organic hybrid top coat that cures to a hard, stain-resistant wearing surface on concrete, Rayson ceramic-hybrid (CH) colour systems and existing resin floors.
Rayson TopShield CH465-S is a two-part, clear inorganic–organic hybrid top coat that cures to a hard, stain-resistant wearing surface on concrete, Rayson ceramic-hybrid (CH) colour systems and existing resin floors.
2. Recommended uses
Clear finishing coat for car park, warehouse and office floors
Sealing coat over FloorGuard CH340-W coloured systems
Clear system on old or polished concrete with PrimeBond CH145-S
Upgrading epoxy, PVC-tile and stone floors with a harder, stain-resistant surface
Dry storage and circulation areas in food, pharmaceutical and healthcare buildings
3. Suitable substrates
Concrete and cement mortar primed with PrimeBond CH145-S or TopShield CH460-S
Existing epoxy floors, PVC tiles and stone such as marble — abrade where needed and test first
4. Key properties
Hard, abrasion-resistant clear wearing surface
Stain-resistant and easy to clean
Resistant to water and common chemicals
Bonds to concrete, cement mortar, epoxy floors, PVC tiles and stone
Recoat in 4 hours; foot traffic after 12 hours
Abrasion resistance
5. System role
Finish.
Figure 1 — Typical system build-up (top to bottom). Layer thicknesses are system-dependent; confirm the specification for your project.
6. Technical data
Surface preparation
The surface below must be clean, dry and free of dust. Concrete: prepare mechanically and prime with PrimeBond CH145-S or TopShield CH460-S. FloorGuard CH340-W: allow 24 hours at 20 °C. Existing epoxy, PVC or stone floors: clean, abrade to a uniform key where needed and confirm adhesion on a test area.
Mixing / dilution
Shake or stir each part. Pour Part B into Part A (3:1 by weight, 13.5 kg : 4.5 kg) and mix for at least 3 minutes with a slow-speed electric mixer (about 600 rpm). Use within 40 minutes at 20 °C — sooner in hot weather. Do not dilute.
Application method
Roller, Brush, Spray
Coverage
0.10–0.15 kg/m² per coat. Clear system: two to three coats. Over FloorGuard CH340-W or epoxy: one coat at 0.10 kg/m².
Application conditions
Substrate dry, with concrete moisture content below 8%, and at least 3 °C above dew point. Protect from rain, water and condensation during cure. Ventilate enclosed areas.
Drying & curing
Foot traffic after 12 hours; full hardness after 72 hours at 20 °C.
Recoat interval
4 to 24 hours between coats. After 24 hours, abrade lightly and clean before recoating.
Film / thickness
About 50 µm per coat; about 100 µm in two coats. Build in thin coats, never one heavy coat.
Pack sizes
18 kg set: Part A 13.5 kg, Part B 4.5 kg
Storage
Store sealed in original packaging in a cool, dry, shaded place at 5–30 °C. Keep away from heat and direct sunlight.
Shelf life
12 months unopened.
7. Application workflow
Figure 2 — Application workflow. Each stage is a hold point: confirm the previous stage is complete and within specification before proceeding.
8. Recommended system
Coloured floor — sound concrete
Prime prepared concrete with Rayson PrimeBond CH140 and repair with Rayson PatchBond EP220 epoxy repair compound
Apply two coats of Rayson FloorGuard CH340-W colour coat, at least 2 hours apart
After 24 hours, seal with one coat of Rayson TopShield CH465-S at 0.10 kg/m²
Clear system on concrete
Grind, repair and vacuum the concrete floor
Prime with one coat of Rayson PrimeBond CH145-S at about 0.15 kg/m²
Apply two coats of Rayson TopShield CH465-S at 0.10 kg/m² each, at least 4 hours apart
Clear upgrade over an epoxy floor
Install or retain a sound epoxy floor — for example Rayson PrimeBond EP110 and Rayson FloorGuard EP310
Clean the cured epoxy, abrade to a uniform matt key and vacuum
Apply one coat of Rayson TopShield CH465-S at 0.10 kg/m² — confirm adhesion on a test area first
9. Limitations
Substrate must be dry (concrete moisture content below 8%) and free of dust and contamination
Use mixed material within its pot life; pot life is shorter in hot weather and in large batches
Thin-film coating — it does not level rough surfaces or bridge moving cracks
Smooth clear finishes can be slippery when wet — specify anti-slip aggregate where needed
Not for hot wash-down, thermal-shock or permanently wet areas — use Rayson FloorGuard PC330-W
Always complete a test area on existing coatings, PVC tiles and stone
10. Health & safety
Two-part reactive product. Wear gloves and eye protection and ensure good ventilation, particularly when spraying. Avoid skin and eye contact — reactive resins can irritate and sensitise skin. Keep away from heat and ignition sources. Keep out of reach of children. Consult the Safety Data Sheet (in preparation) before use.