RAYSON HIGH PERFORMANCE COATINGS

Technical Data Sheet

DocumentRY-TDS-CH460
RevisionRev. 1.0
Issue dateSeptember 2026
StatusIssued

Rayson TopShield CH460-S

Rayson TopShield · Top coats & sealers

Draft data sheet. Hardness, abrasion and chemical resistance are described without test figures; the test reports and the Safety Data Sheet (hazard classification, flash point, VOC) are in preparation — confirm with the Rayson technical team.

Ask a technical question Download current PDF WhatsApp us

1. Product description

Rayson TopShield CH460-S is a two-part, clear inorganic–organic hybrid coat that penetrates concrete and cures to a hard, dust-free, stain-resistant surface, used as a floor hardening system or as the primer coat under TopShield CH465-S.

Rayson TopShield CH460-S is a two-part, clear inorganic–organic hybrid coat that penetrates concrete and cures to a hard, dust-free, stain-resistant surface. It is used as a floor hardening system or as the primer coat under TopShield CH465-S.

2. Recommended uses

  • Hardening and dust-proofing concrete floors in warehouses, factories and car parks
  • Clear sealing of concrete and cement mortar floors in offices and plant areas
  • Primer coat under TopShield CH465-S clear top coat
  • Upgrading the surface of existing concrete, mortar, epoxy and stone floors

3. Suitable substrates

  • New (fully cured) and old concrete, cement mortar and screed; moisture content below 8%
  • Existing epoxy floors and natural stone such as marble — test area first
  • Other substrates: confirm suitability with the technical team

4. Key properties

  • Penetrates and binds the concrete surface
  • Hard, abrasion-resistant, dust-free finish
  • Stain-resistant and easy to clean
  • Resistant to water and common chemicals
  • Foot traffic after 12 hours; full hardness in 72 hours
  • Abrasion resistance

5. System role

Standalone coating.

Rayson TopShield CH460-S — coats 2 and 3 This product · 0.10 kg/m² each, after polishing Rayson TopShield CH460-S — coat 1 This product · 0.15 kg/m², penetrating coat Prepared concrete substrate Repaired, ground and vacuumed

Figure 1 — Typical system build-up (top to bottom). Layer thicknesses are system-dependent; confirm the specification for your project.

6. Technical data

Surface preparation Concrete must be dry and clean, with moisture content below 8%. Repair cracks and damaged areas first. Remove laitance, dust, oil, old coatings and efflorescence by grinding, sanding or blasting, then vacuum thoroughly.
Mixing / dilution Shake or stir each part. Mix Part A : Part B = 5:1 by weight (15 kg : 3 kg) for 2 minutes with a slow-speed mixer (about 600 rpm). Use within 40 minutes at 20 °C — sooner in hot weather. Do not dilute.
Application method Roller, Rubber rake, Brush, Airless spray
Coverage Hardening system: coat 1 at 0.15 kg/m², coats 2 and 3 at 0.10 kg/m² each (0.35 kg/m² in total). As a primer coat: 0.10–0.15 kg/m².
Application conditions Apply to a dry substrate at least 3 °C above dew point. Protect from rain, water and condensation during cure. Ventilate enclosed areas.
Drying & curing Foot traffic and light work after 12 hours; full hardness after 72 hours at 20 °C.
Recoat interval 4 to 24 hours between coats. In the hardening system, polish and burnish between coat 1 and coat 2.
Film / thickness Thin, penetrating coats — consumption governs film. Build in two to three coats, never one heavy coat.
Pack sizes 18 kg set: Part A 15 kg, Part B 3 kg
Storage Store sealed in original packaging in a cool, dry, shaded place at 5–30 °C. Keep away from heat and direct sunlight.
Shelf life 12 months unopened.

7. Application workflow

1 Inspect Assess substrate & co… 2 Prepare Mechanical prep, repa… 3 Mix Full packs, correct r… 4 Apply Within pot life & con… 5 Recoat Within recoat window 6 Cure Before return to serv…

Figure 2 — Application workflow. Each stage is a hold point: confirm the previous stage is complete and within specification before proceeding.

8. Recommended system

Concrete hardening system

  1. Clean the floor, repair cracks and damaged areas with Rayson PatchBond EP220 epoxy repair compound, grind and vacuum
  2. Apply coat 1 of Rayson TopShield CH460-S by roller at 0.15 kg/m²
  3. After at least 4 hours, polish and burnish with a floor polishing machine
  4. Apply coats 2 and 3 at 0.10 kg/m² each by rubber rake, roller or airless spray, at least 4 hours apart

Primer coat under TopShield CH465-S

  1. Prepare, repair and vacuum the concrete
  2. Apply one coat of Rayson TopShield CH460-S at 0.10–0.15 kg/m²
  3. Without polishing, apply Rayson TopShield CH465-S clear top coat within 4 to 24 hours

9. Limitations

10. Health & safety

Two-part reactive product. Wear gloves and eye protection and ensure good ventilation, particularly when spraying. Avoid skin and eye contact — reactive resins can irritate and sensitise skin. Keep away from heat and ignition sources. Keep out of reach of children. Consult the Safety Data Sheet (in preparation) before use.

Ask a technical question WhatsApp us