Technical Data Sheet
| Document | RY-TDS-CH140 |
|---|---|
| Revision | Rev. 1.0 |
| Issue date | September 2026 |
| Status | Issued |
Rayson PrimeBond · Primers & bonding coats
Rayson PrimeBond CH140 is a single-pack, ready-to-use primer that seals prepared, sound concrete and anchors the Rayson ceramic-hybrid (CH) colour and clear coats — FloorGuard CH340-W and TopShield CH465-S — to the floor.
Rayson PrimeBond CH140 is a single-pack, ready-to-use primer that seals prepared, sound concrete and anchors the Rayson ceramic-hybrid (CH) colour and clear coats to the floor.
Primer.
Figure 1 — Typical system build-up (top to bottom). Layer thicknesses are system-dependent; confirm the specification for your project.
| Surface preparation | Concrete must be sound, dry and clean, with moisture content below 8%. Remove laitance, dust, oil, old coatings and efflorescence by diamond grinding, sanding or blasting, then vacuum thoroughly. Preparation decides the result — do not coat over dust or contamination. |
|---|---|
| Mixing / dilution | Single pack. Stir before use. Do not dilute with water or thinner. |
| Application method | Roller, Brush |
| Coverage | 0.10–0.15 kg/m² in one coat, depending on substrate porosity |
| Application conditions | Apply to a dry substrate at least 3 °C above dew point. Protect from rain, water and condensation until dry. Ventilate enclosed areas. |
| Drying & curing | Allow to dry fully — at least 2 hours in normal conditions — before repairs or the next coat. Drying is slower in cool or humid conditions. |
| Recoat interval | Overcoat with FloorGuard CH340-W once fully dry (minimum 2 hours). Confirm the maximum overcoat window with the Rayson technical team. |
| Film / thickness | Penetrating primer; consumption governs film. |
| Pack sizes | Single pack. Confirm pack size with the Rayson technical team. TECHNICAL REVIEW REQUIRED |
| Storage | Store sealed in original packaging in a cool, dry, shaded place at 5–30 °C. Keep away from heat and direct sunlight. |
| Shelf life | See batch label; use unopened material within the stated period. TECHNICAL REVIEW REQUIRED |
Figure 2 — Application workflow. Each stage is a hold point: confirm the previous stage is complete and within specification before proceeding.
Coloured floor system — sound concrete
Anti-slip coloured floor
Wear gloves and eye protection and ensure good ventilation. Avoid skin and eye contact. Keep containers closed when not in use. Keep out of reach of children. Consult the Safety Data Sheet (in preparation) before use.