RAYSON HIGH PERFORMANCE COATINGS

Technical Data Sheet

DocumentRY-TDS-AC505
RevisionRev. 1.1
Issue dateOctober 2026
StatusIssued

Rayson SealForce AC505-W

Rayson SealForce · Waterproofing primer, membranes & additive

Ask a technical question Download current PDF WhatsApp us

1. Product description

Rayson SealForce AC505-W is a one-part, water-based acrylic primer for the SealForce waterproofing range — brushed or rolled onto concrete, render, brick, stone and roof tiles to seal pores, bind dust and give SealForce AC540-W a firm surface to bond to.

SealForce AC505-W is the first coat of Rayson's acrylic roof and wall system: a milky-white acrylic dispersion in water, stirred and applied straight from the pail by brush or roller. It soaks into the surface, binds loose dust, firms weak surface layers and seals the pores, then dries to a clear film — the change from white to clear shows when it is ready for the membrane.

2. Recommended uses

  • Primer for absorbent concrete, render, brick, stone and tiles before SealForce AC540-W
  • Bonding primer on smooth, dense concrete finishes
  • Binding surface dust and firming weak surface layers before the membrane
  • Sealing pores in rough concrete so the membrane cures without bubbles or pinholes

3. Suitable substrates

  • Concrete and cementitious surfaces: sound, with a pull-off strength of at least 1.5 N/mm², at least 28 days old and mechanically prepared to an open texture
  • Brick and stone with sound, flush-pointed mortar joints; loose units replaced
  • Unglazed ceramic tiles and clay roof tiles, securely fixed, with broken or missing tiles replaced
  • All surfaces power-washed or vacuumed free of dust, and dry: moisture at most 6% by weight, with no standing water or rising moisture

4. Key properties

  • One-part and water-based — stirred and applied straight from the pail by brush or roller
  • Improves the bond of SealForce AC540-W to concrete, render, masonry and tiles
  • Seals pores so the membrane cures without bubbles or pinholes
  • Binds surface dust and firms weak surface layers
  • Goes on milky white and dries clear, so it is easy to see when it is ready to coat

5. System role

Primer.

Rayson SealForce AC540-W membrane Two or three coats, per system Rayson SealForce AC505-W primer This product · dries clear Prepared concrete, masonry, tile Sound, clean, dry

Figure 1 — Typical system build-up (top to bottom). Layer thicknesses are system-dependent; confirm the specification for your project.

6. Technical data

Surface preparation Surfaces must be sound, clean and dry, free of standing water, dust, oil, grease, laitance, curing compounds and loose or friable material; remove dust by industrial vacuuming or power-washing. Concrete must be at least 28 days old, with a pull-off strength of at least 1.5 N/mm², mechanically prepared to an open texture; repair cracks, voids and spalls with Rayson PatchBond EP220 and let the repairs cure. Brick and stone need sound, flush-pointed joints; tiles must be securely fixed, with broken or missing ones replaced, then power-washed and dried. Confirm adhesion with a small trial.
Mixing / dilution One part, ready to use — stir for at least 1 minute with a slow paddle until uniform, without whipping in air
Application method Brush, Roller
Coverage Approximately 0.1–0.3 kg/m² per coat, depending on absorbency; a 20 kg pail primes about 65–200 m² per coat. Very porous surfaces take a second coat
Application conditions Air and substrate between +5 °C and +40 °C; relative humidity at most 80%; substrate and fresh primer at least 3 °C above the dew point. Substrate moisture at most 6% by weight, visibly dry, with no standing water and no rising moisture. Protect from rain until dry.
Drying & curing Dry when the milky white has turned clear — about 30 minutes, longer in cool or humid weather. Apply SealForce AC540-W once it has dried clear. Protect from rain until dry
Recoat interval Overcoat with Rayson SealForce AC540-W once the primer has dried clear, after about 30 minutes; longer in cool or humid weather. On very porous surfaces, a second primer coat goes on once the first has dried clear.
Film / thickness Penetrating primer: about 0.1–0.3 kg/m² per coat, depending on absorbency. One coat, two on very porous surfaces. Applied milky white; dries to a clear film.
Pack sizes 20 kg pail
Storage Store in original, unopened and undamaged packaging in dry conditions, between +5 °C and +30 °C.
Shelf life 12 months from the date of production.

7. Application workflow

1 Inspect Assess substrate & co… 2 Prepare Mechanical prep, repa… 3 Mix Full packs, correct r… 4 Apply Within pot life & con… 5 Recoat Within recoat window 6 Cure Before return to serv…

Figure 2 — Application workflow. Each stage is a hold point: confirm the previous stage is complete and within specification before proceeding.

8. Recommended system

Concrete or rendered roof and wall, before SealForce AC540-W

  1. Prepare the surface mechanically; repair cracks, voids and spalls with Rayson PatchBond EP220 and let the repairs cure
  2. Vacuum all dust; the surface must be dry, with no standing water
  3. Apply one coat of Rayson SealForce AC505-W at about 0.1–0.3 kg/m² by brush or roller; a second coat on very porous concrete
  4. When it has dried clear, about 30 minutes later, apply Rayson SealForce AC540-W

Old roof tiles, brick or stone, before SealForce AC540-W

  1. Fix loose tiles or units, replace broken or missing ones and point open mortar joints
  2. Power-wash the surface and allow it to dry
  3. Apply one coat of Rayson SealForce AC505-W at about 0.1–0.3 kg/m²
  4. When it has dried clear, apply Rayson SealForce AC540-W in two coats

9. Limitations

10. Health & safety

Water-based product. Wear gloves and eye protection; ensure reasonable ventilation. Avoid skin and eye contact; clean tools with water while wet. Keep out of reach of children. Consult the Safety Data Sheet (in preparation) before use.

Ask a technical question WhatsApp us